Feedback
Nexans
Installation cable fire-resistant ALSECURE PREMIUM 300/500 V, Nexans
ALSECURE PREMIUM 3G2.5 (*5)
Article number: Suppl. article no:
0474110
27010191000
to see price and stock
ALSECURE® PREMIUM is a halogen free, fireproof, unshielded installation cable. The cable is intended for fixed installation on ladders, directly on the wall and in pipes or ducts. Used when there is a requirement for functionality during and after a fire in, for example, emergency lighting, fire alarm system and control system.
ALSECURE® PREMIUM cables are designed for use in security systems (emergency lighting, fire alarm systems, etc) in all public areas, such as concert halls, theatres, cinemas, shops, hospitals, schools, high-rise buildings, tunnels and industries. ALSECURE® PREMIUM cables, are fireproof and flame retardant, have low smoke development and are halogen-free. If a fire occurs, the flue gases are low- corrosive.
ALSECURE® PREMIUM cables must be installed in accordance with applicable regulations and standards, and must be protected against direct sunlight during outdoor installation.
When installing between 0 ° C and -10 ° C, the cable must be heated at least 48 hours before installation. ALSECURE® PREMIUM is not suitable for placing in ground.
Fire classes: Fire resistant in accordance with NF C 32-070 Cat. CR1, IEC 60331, EN 50200, EN 1363, NBN C 30-004 FR2 Rf2h. Flame spread class according to NF C 32-070 Cat. C1 & C2, IEC 60332 Part 2 & 1, EN 50266, NBN C 30-004 F2. Low smoke development: NF C 32-073, IEC 61034, EN 50268. Halogen-free : NF C 32-074, IEC 60754, EN 50267. Smoke gases : NF C 32-074, IEC 60754, EN 50267. Low-corrosive : NF C 32-074, IEC 60754, EN 50267
Design: Wire: copper. Insulation: halogen-free thermoplastic INFIT™ technology. Outer jacket: HFFR (polyolefin without halogens).
ALSECURE® PREMIUM cables are designed for use in security systems (emergency lighting, fire alarm systems, etc) in all public areas, such as concert halls, theatres, cinemas, shops, hospitals, schools, high-rise buildings, tunnels and industries. ALSECURE® PREMIUM cables, are fireproof and flame retardant, have low smoke development and are halogen-free. If a fire occurs, the flue gases are low- corrosive.
ALSECURE® PREMIUM cables must be installed in accordance with applicable regulations and standards, and must be protected against direct sunlight during outdoor installation.
When installing between 0 ° C and -10 ° C, the cable must be heated at least 48 hours before installation. ALSECURE® PREMIUM is not suitable for placing in ground.
Fire classes: Fire resistant in accordance with NF C 32-070 Cat. CR1, IEC 60331, EN 50200, EN 1363, NBN C 30-004 FR2 Rf2h. Flame spread class according to NF C 32-070 Cat. C1 & C2, IEC 60332 Part 2 & 1, EN 50266, NBN C 30-004 F2. Low smoke development: NF C 32-073, IEC 61034, EN 50268. Halogen-free : NF C 32-074, IEC 60754, EN 50267. Smoke gases : NF C 32-074, IEC 60754, EN 50267. Low-corrosive : NF C 32-074, IEC 60754, EN 50267
Design: Wire: copper. Insulation: halogen-free thermoplastic INFIT™ technology. Outer jacket: HFFR (polyolefin without halogens).
- Article number: 0474110
- Suppl. article no: 27010191000
- Ean no: 7330000095182
- Material class QA6400
Technical data
- Cable type: ALSECURE PREMIUM
- Number of cores: 3
- Nominal cross section conductor: 2.5 mm²
- With protective conductor: Yes
- Outer diameter approx.: 9.95 mm
- Weight/100 m: 17.6 kg
- Nominal voltage U0: 300 V
- Shape of conductor: Round
- Nominal voltage U: 500 V
- Permitted cable outer temperature during assembling/handling: -10-50 °C
- Permitted cable outer temperature after assembling without vibration: -40-90 °C
- Dimension conductor x area: 3G2,5 mm²
- Colour outer sheath: Orange
- Weight: 165 kg/km
- Max. conductor temperature: 90 °C
- Screen: No
- Drain wire: No
- Reaction-to-fire according to EN 13501-6: Class: None
- Protective barrier: None
- Armouring/reinforcement: None
- Conductor category: Class 1 = solid
- Conductor material: Copper
- Material outer sheath: Polyolefin
- Core identification: Colour
- Reaction-to-fire according to EN 13501-6: Smoke production: None
- Material core insulation: Polyolefin
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles: None
- Certified for shipboard application: No
- Certified as airport lighting cable: No
- Cable geometry: Round
- Low temperature resistant according to EN 60811-504+505+506: Yes
- Conductor resistance at 20 °C: 7.41 Ohm/km
- Conductor surface: Bare
- Suitable as installation cable: Yes
- Min. permitted bending radius, stationary application/permanent installation: 59.7 mm
- Core identification according to HD 308 S2: Yes
- Oil resistant according to EN IEC 60811-404: No
- Specification material outer sheath: Other
- Reaction-to-fire according to EN 13501-6: Acidity: None
- Twisted cores: No
- REACH Date: 2021-06-14
- Low smoke (according to EN 61034-2): Yes
- Insulation integrity: PH 90
- Halogen free according to EN 60754-1/2: Yes
- Flame retardant: According to IEC/EN 60332-3-24
- REACH Information obligation: No