Feedback
Schneider Electric
Modicon M251
CONTROLLER M251-2XETHERNET TM251MESE
Article number: Suppl. article no:
4508197
TM251MESE
to see price and stock
The product is aimed at machine builders. The software used for programming is called SoMachine > 4. Can be combined with accessories TM3 and TM4.
- Article number: 4508197
- Suppl. article no: TM251MESE
- Ean no: 3606480648878
- Material class QP720B
Technical data
- Packagin Size: 1 ST/10 ST
- Number of interfaces PROFINET: 0
- Number of HW-interfaces wireless: 0
- Number of analogue inputs: 0
- Number of analogue outputs: 0
- Number of digital inputs: 0
- Number of digital outputs: 0
- Number of HW-interfaces RS-232: 1
- Number of HW-interfaces RS-422: 0
- Number of HW-interfaces RS-485: 1
- Number of HW-interfaces USB: 1
- Number of HW-interfaces other: 0
- Number of HW-interfaces industrial Ethernet: 3
- Number of HW-interfaces parallel: 0
- Width: 54 mm
- Depth: 95 mm
- Explosion safety category for gas: None
- Explosion safety category for dust: None
- Additional program memory possible: Yes
- Suitable for safety functions: No
- Supply voltage DC: 19.2-28.8 V
- Height: 90 mm
- IO link master: No
- Supporting protocol for LON: No
- Long-Term Evolution (LTE): No
- Number of relay outputs: 0
- Max. number of time switches: 0
- With display: No
- Memory size: 64000 kByte
- Model: Modular
- With optical interface: No
- Front built-in possible: No
- Processing time (1K, binary operation): 0.022 ms
- Rack-assembly possible: No
- Radio standard WLAN 802.11: No
- Redundancy: No
- SIL according to IEC 61508: None
- Suitable for rail mounting: Yes
- Radio standard GPRS: No
- Radio standard GSM: No
- Radio standard UMTS: No
- Supporting protocol for ASI: No
- Supporting protocol for CAN: No
- Supporting protocol for Data-Highway: No
- Supporting protocol for DeviceNet: No
- Supporting protocol for KNX: No
- Supporting protocol for INTERBUS-Safety: No
- Supporting protocol for INTERBUS: No
- Supporting protocol for Modbus: Yes
- Supporting protocol for SERCOS: No
- Supporting protocol for SUCONET: No
- Supporting protocol for TCP/IP: Yes
- Supporting protocol for other bus systems: No
- Supporting protocol for AS-Interface Safety at Work: No
- Supporting protocol for DeviceNet Safety: No
- Supporting protocol for EtherNet/IP: Yes
- Supporting protocol for Foundation Fieldbus: No
- Supporting protocol for PROFINET CBA: No
- Supporting protocol for PROFINET IO: No
- Supporting protocol for PROFIsafe: No
- Supporting protocol for SafetyBUS p: No
- System accessory: No
- Appendant operation agent (Ex ia): No
- Appendant operation agent (Ex ib): No
- Voltage type (supply voltage): DC
- Type of memory: NVRAM
- Wall mounting/direct mounting: Yes
- Performance level according to EN ISO 13849-1: None
- Supporting protocol for IEC 61850 Ethernet: No
- Supporting protocol for DNP3: No
- Supporting protocol for IEC 60870: No
- Radio standard Bluetooth: No
- Supporting protocol for PROFIBUS: No
- REACH contains candidate substances: Bly | 1,2-dimetoxietan, Dimethyl Glycol, 1,2-dimethoxyethane
- REACH Date: 2022-07-20
- REACH Information obligation: Yes