Frequency converter Altivar Machine 320 Book

ATV320 0,37KW 230V 1PH BOOK ATV320U04M2B
Article number: 
3345311
Suppl. article no: 
ATV320U04M2B





 to see price and stock
Denna produkt innehåller ett eller flera ämnen på kandidatförteckningen.
Altivar Machine 320 is particularly suitable for use in applications involving simple to complex industrial machines. With built-in security features, integrated mini PLC, and open to many communication protocols.
The choice of the right circuit breaker and contactor is easily made from finished tables in the catalog
Flexible format
With two different physical formats, compact and book size. 0.18 - 4kW, fits ATV320 in both standard electrical cabinets and in tight spaces.
Extra Communication Card for most requested fieldbuses: Profibus DP, ProfiNet, Ethernet IP - Modbus TCP, DeviceNet
Physical format
B = Bok
C = Compact
  • Article number: 
    3345311
  • Suppl. article no: 
    ATV320U04M2B
  • Ean no: 
    3606480966323
  • Material class 
    QO571B
Technical data
  • Packagin Size: 1 ST/24 ST
  • Type: ATV320U04M2B
  • Design: Beech
  • Number of phases input: 1
  • Mains voltage: 200-240 V
  • Nominal output current I2N: 3.3 A
  • Max. output at linear load at rated output voltage: 0.37 kW
  • Max. output at quadratic load at rated output voltage: 0.37 kW
  • Height: 325 mm
  • Width: 45 mm
  • Depth: 245 mm
  • Type of converter: U converter
  • Application in industrial area permitted: Yes
  • Application in domestic- and commercial area permitted: No
  • Max. output voltage: 240 V
  • Degree of protection (IP): IP20
  • Number of phases output: 3
  • Supporting protocol for PROFIsafe: No
  • Supporting protocol for CAN: Yes
  • Supporting protocol for Data-Highway: No
  • Supporting protocol for TCP/IP: No
  • Supporting protocol for INTERBUS-Safety: No
  • Integrated breaking resistance: No
  • Supporting protocol for PROFINET IO: Yes
  • Supporting protocol for SafetyBUS p: No
  • Number of analogue inputs: 3
  • Number of analogue outputs: 1
  • Number of digital inputs: 6
  • Number of digital outputs: 1
  • Number of HW-interfaces other: 1
  • Number of HW-interfaces serial TTY: 0
  • Number of HW-interfaces parallel: 0
  • Number of HW-interfaces industrial Ethernet: 1
  • 4-quadrant operation possible: Yes
  • Max. output frequency: 599 Hz
  • With PC connection: Yes
  • With optical interface: No
  • With control element: Yes
  • Mains frequency: 50/60 Hz
  • Relative symmetric net frequency tolerance: 5 %
  • Relative symmetric net voltage tolerance: 10 %
  • Number of HW-interfaces USB: 0
  • Supporting protocol for ASI: No
  • Number of HW-interfaces RS-485: 1
  • Number of HW-interfaces RS-422: 0
  • Supporting protocol for DeviceNet: Yes
  • Supporting protocol for KNX: No
  • Supporting protocol for INTERBUS: No
  • Supporting protocol for Modbus: Yes
  • Number of HW-interfaces RS-232: 0
  • Supporting protocol for SERCOS: No
  • Supporting protocol for SUCONET: No
  • Number of interfaces PROFINET: 0
  • Supporting protocol for LON: No
  • Supporting protocol for other bus systems: Yes
  • Supporting protocol for AS-Interface Safety at Work: No
  • Supporting protocol for BACnet: No
  • Supporting protocol for DeviceNet Safety: No
  • Supporting protocol for EtherNet/IP: Yes
  • Supporting protocol for Foundation Fieldbus: No
  • Supporting protocol for PROFINET CBA: No
  • Supporting protocol for PROFIBUS: Yes
  • REACH contains candidate substances: Bly
  • REACH Date: 2022-07-20
  • REACH Information obligation: Yes