AhlsellProductsElectricAutomation 29-45

Automation 29-45

Do you work with electrical service and automation in properties or workshops? Ahlsell helps you find the right products for you. Whether you work with commercial properties or private residences, we have the range for your needs. Here you will find contractors, buttons, sensors, safety switches, and accessories for easy installation. Learn more about our products here or visit your nearest Ahlsell store.

Timer relay a-collection
a-collection
Timer relay a-collection
Art. no.: 4098560
Function Op, operation delayed: Time calculation starts when the contact on the active input is closed. After the set time the relay switches on regardless of whether the contact on the active input is closed or open. If the contact is closed again after the time calculation has been switched off, the relay turns off and the time calculation starts again.
Function in, delayed disconnection: Time calculation starts and the relay opens when the contact on the active input is closed. After the set time the relay switches off regardless of whether the contact on the active input is closed or open. If the contact is closed again after the time calculation has been completed, the relay turns on and the time calculation starts again.
Function Dr, drop out delayed: The relay opens when the contact on the activation input is closed. When the contact is broken the time calculation starts. After the set time, the relay turns off. If the contact on the active input is closed while the time calculation is being made, the time calculation is reset while the relay is still turned on.
Flashing Function - Function R: (ON time first), (Function, Rb, OFF time first). When the control voltage is connected, the time starts to be calculated, when the period has expired the relay disengages. When the time for the disengaged relay has expired, the relay opens. This process continues as long as the control voltage is connected. The time for the rest and running time is equal. All relevant data, as well as the circuit diagram are clearly marked on the side of the relays.
Indication: 2 LEDs. Green lights up when the control voltage is connected. Yellow lights up when the relay is closed and flashes during the time calculation
Time relay DMB/PMB Multifunction
Carlo Gavazzi
Time relay DMB/PMB Multifunction
Art. no.: 4036450
Feature description
Function Op, switch-on delayed: The timer starts when the contact is active. the entrance is closed. After the set time, the relay switches on regardless of whether the contact is active. the input is closed or broken. If the contact closes again after the timer has finished, the relay switches off and the timer starts again.
Function In, delayed disconnection:The timer starts and the relay switches on when the contact is active. the passage closes. After the set time, the relay switches off regardless of whether the contact is active. the input is closed or broken. If the contact closes again after the timer has finished, the relay switches on and the timer starts again.
Function Dr, switch-off delayed:The relay switches on when the contact on the activation input is closed. When the contact is broken, the timer starts. After the set time, the relay switches off. If the contact on the active input is closed while the time count is in progress, the time count is reset while the relay is still switched on.
Blinking function - Function R:(ON time first), (Function Rb, OFF time first) When the control voltage is connected, the time count starts, when the time has expired the relay closes. When the time for the pulled relay has expired, the relay drops. This process continues as long as the control voltage is connected. The time for break and walking time are equal.
All relevant data and wiring diagrams are clearly marked on the side of the relays.
Time relay DMB/PMB MultifunctionTime relay DMB/PMB Multifunction
Voltage measurement relay 3-phase for over and under voltage
Carlo Gavazzi
Voltage measurement relay 3-phase for over and under voltage
Art. no.: 3864692
3-phase monitoring relays for phase sequence/Phase break and Over-/Under Voltage for mounting on DIN rails or 11-pin base.
Functional description
The relay is pulled when the phases or the phases + 0 are within the set limits, the relay falls if the limit values are passed after the set time delay (0.1-30s). The relay also monitors phase breaks and phase sequence, at the wrong phase sequence or phase break the relay falls without time delay.
All relevant data, as well as the circuit diagram are clearly marked on the side of the relays.3 LEDs. Green lights up when the control voltage is connected. Yellow lights up when the relay is on and Red flashes during the time, and is lit with a steady light in alarm.
Miniature relay C7 and C9 QRCplus
Releco
Miniature relay C7 and C9 QRCplus
Art. no.: 4016417
A real compact relay with base, when you are looking for a small relay with the big relay's contact data. With touch-protected test button which is non-locking with pressing and remaining in extracted mode. Accessories include test buttons using only the non-locking function or blind plug (if the test function is not desired). The test button is colour-coded, red for AC and DC blue, as well as the most common voltages 230VAC, 24VAC and 24VDC has its own colour shades. The coil input voltage is clearly marked on the relay front and on the coil. CE certified.
Types C7A ... and C9A.. have mechanical indication of actuated contacts.
Types C7A..X and C9A..X.. have mechanical indication of activated contacts and LED indication of actuated relay coil
Showing 52 of 1110