Back-suction protection SYR 6610 BA, Somatherm
Backflow preventer BA 6610 R15 Backflow preventer BA 6610 R15
Article number: Suppl. article no:
5045394V
5045394
to see price and stock
SYR 6610 BA is a controllable non-return valve approved for liquids up to category 4 according to SS-EN 1717. The valve's task is to prevent contaminated drinking water from being transferred to the public or internal drinking water network. The back-suction protection consists of two back-mounted non-return valves with a pipe break and drain connection between.
SYR 6610 BA is used, among other things, for filling systems that contain water with or without antifreeze.
SYR 6610 BA is used, among other things, for filling systems that contain water with or without antifreeze.
- Article number: 5045394V
- Suppl. article no: 5045394
- Ean no: 4017905239400
- Material class PIC100
- This is an alternative to item 5021081
Technical data
- Connection 1: External thread
- Connection 2: External thread
- Nominal diameter connection 1: 1/2 inch (15)
- Nominal diameter connection 2: 1/2 inch (15)
- Flange standard: None
- Height: 165 mm
- Built-in position: Horizontal
- Built-in length: 201 mm
- Fitting length with screw connection: 201 mm
- Suitable for potable water: Yes
- Housing material: Brass
- Max. medium temperature (continuous): 65 °C
- Nominal flow rate: 2.9 m³/h
- Article compression class: PN 10
- Outer pipe diameter drainage connection: 40 mm
- Fluid category according to EN 1717: 4
- Backflow safeguard according to EN 1717: BA
- Position indicator: No
- Max. inlet pressure: 10 bar