Feedback

  • https://www.youtube.com/watch?v=/external-assets/JPEGlarge800_800/45/94/ProductImage67874594.jpg
  • https://www.youtube.com/watch?v=/external-assets/JPEGlarge800_800/23/22/ProductImage35702322.jpg
Nexans

Connecting cable RQ FT (H05Z1-K FT) 300/500V 0.75-1.0mm² Dca

RQ FT 0.75 300/500V GREY R100 (*2)
Article number: 
0345482
Suppl. article no: 
11198240-870-02





 to see price and stock
Produkten är miljöbedömd av SundaHusProdukten är bedömd hos Byggvarubedömningen med totalbedömningen Accepteras.
The cable is primarily intended to be used for fixed protected installation of signal and control circuits in appliances. H05Z1-K is a halogen-free, HFFR-insulated, coupling line with a round multi-threaded conductor with area 0.75 -1.0 mm² of tinplate copper. The cable is designed in accordance with SS EN 50525-3-31. The conductor has resistance according to IEC 60228 class 5. The insulation is marked “NEXANS GS H05Z1-K area mm²". H05Z1-K meets fire spread class D. The cable is approved by SEMKO.
  • Article number: 
    0345482
  • Suppl. article no: 
    11198240-870-02
  • Ean no: 
    7330000084520
  • Replaces art.nbr: 
    0358792
  • Material class 
    QA4850
Technical data
  • Packagin Size: 100 M/24000 M
  • Cable type: RQ FT
  • Dimension conductor x area: 1x0,75 mm²
  • Core colour: Grey
  • Diameter conductor: 2 mm
  • Outer diameter approx.: 2.3 mm
  • Screen: No
  • Reaction-to-fire according to EN 13501-6: Class: Dca
  • Permitted cable outer temperature during assembling/handling: -10-50 °C
  • Low temperature resistant according to EN 60811-504+505+506: Yes
  • Permitted cable outer temperature after assembling without vibration: -40-70 °C
  • Conductor category: Class 5 = flexible
  • Nominal voltage U0: 300 V
  • Nominal voltage U: 500 V
  • Material core insulation: Polyolefin
  • Nominal cross section conductor: 0.75 mm²
  • Number of cores: 1
  • Armouring/reinforcement: None
  • Drain wire: No
  • Reaction-to-fire according to EN 13501-6: Flaming droplets/particles: d2
  • Conductor material: Copper
  • Conductor surface: Tinned
  • Max. permitted conductor temperature: 70 °C
  • Min. permitted bending radius, stationary application/permanent installation: 9.2 mm
  • Core identification: Colour
  • Reaction-to-fire according to EN 13501-6: Smoke production: s2
  • Protective barrier: None
  • Reaction-to-fire according to EN 13501-6: Acidity: a2
  • Certified for shipboard application: No
  • Certified as airport lighting cable: No
  • Cable geometry: Round
  • Shape of conductor: Round
  • Conductor resistance at 20 °C: 26.7 Ohm/km
  • Suitable as installation cable: Yes
  • Core identification according to HD 308 S2: Yes
  • Weight: 11 kg/km
  • REACH Date: 2021-06-14
  • Weight/100 m: 1.3 kg
  • REACH Information obligation: No
  • Halogen free according to EN 60754-1/2: Yes
  • Low smoke (according to EN 61034-2): Yes
  • Insulation integrity: None