Feedback
Siemens
IO-Link DI 8x24V, 8xM8, AL
ET 200AL. IO-LINK. DI 8X24VDC 6ES7141-5BF00-0BL0
Article number: Suppl. article no:
4504975
6ES7141-5BF00-0BL0
to see price and stock
IO-Link module, ET 200AL, Digital Inputs DI 8x24V DC, 8xM8, IP65/67
- Article number: 4504975
- Suppl. article no: 6ES7141-5BF00-0BL0
- Ean no: 4047623411369
- Material class QP8130
Technical data
- Type: 6ES7141-5BF00-0BL0
- Number of digital inputs: 8
- Number of digital outputs: 0
- Width: 30 mm
- Number of interfaces PROFINET: 0
- Number of HW-interfaces wireless: 0
- Digital inputs configurable: Yes
- Number of HW-interfaces RS-232: 0
- Number of HW-interfaces RS-422: 0
- Input current at signal 1: 3 mA
- Number of HW-interfaces RS-485: 0
- Number of HW-interfaces USB: 0
- Permitted voltage at input: -30-30 V
- Number of HW-interfaces industrial Ethernet: 0
- Type of digital output: None
- Fieldbus connection over separate bus coupler possible: Yes
- IO link master: No
- Suitable for safety functions: No
- System accessory: Yes
- Supply voltage DC: 18-30 V
- Number of HW-interfaces parallel: 0
- Radio standard WLAN 802.11: No
- Number of HW-interfaces serial TTY: 0
- Supporting protocol for PROFIsafe: No
- Number of HW-interfaces other: 0
- Supporting protocol for ASI: No
- Supporting protocol for Modbus: No
- Supporting protocol for SERCOS: No
- Supporting protocol for TCP/IP: No
- Supporting protocol for AS-Interface Safety at Work: No
- Supporting protocol for PROFINET IO: No
- Supporting protocol for SafetyBUS p: No
- Depth: 40 mm
- Height: 159 mm
- With optical interface: No
- Front built-in possible: Yes
- Rack-assembly possible: No
- Radio standard Bluetooth: No
- Radio standard GPRS: No
- Radio standard GSM: No
- Radio standard UMTS: No
- Suitable for rail mounting: Yes
- Supporting protocol for CAN: No
- Supporting protocol for Data-Highway: No
- Supporting protocol for DeviceNet: No
- Supporting protocol for DeviceNet Safety: No
- Supporting protocol for EtherNet/IP: No
- Supporting protocol for Foundation Fieldbus: No
- Supporting protocol for INTERBUS: No
- Supporting protocol for INTERBUS-Safety: No
- Supporting protocol for KNX: No
- Supporting protocol for LON: No
- Supporting protocol for PROFIBUS: No
- Supporting protocol for PROFINET CBA: No
- Supporting protocol for SUCONET: No
- Supporting protocol for other bus systems: No
- Appendant operation agent (Ex ia): No
- Appendant operation agent (Ex ib): No
- Wall mounting/direct mounting: Yes
- Time delay at signal change: 1.2-4.8 ms
- REACH contains candidate substances: Blysilikat, Lead silicate 1.5PbO.cntdot.SiO2
- REACH Date: 2024-02-06
- REACH Information obligation: Yes